X - ray inspection procedures
2017-10-20 08:08:11
With the use of security machines more and more widely, the occasional replacement of security personnel is inevitable. In general, the main attention to the following aspects can be:
   First, there is an operation permit on the job, undocumented not work, the boss wear a good labor protection;
   Second, the boot preparation: check the machine shell with or without exception; check the equipment power insurance and operating field power line voltage is in line with the provisions (non-380V voltage operation); check the exposure curve, sensitization, sensitivity, etc. meet the best parameters, The film for the determination of the parameters; 20 meters radius to draw the radiation safety zone, and produce warning signs or warning lights.
    1) boot: check the operation of the rotary position is correct; power to start high pressure, depending on whether the high pressure indicator light, all normal after the operation; operation should take distance, time, shielding protection; in the course of the operation, Moving the knob and the cable head; prohibited overload operation.
    2) Shutdown: pull off the power switch, the operation of the spin back to the specified location; clean up the equipment health, pay attention to equipment storage safety; running records fill in time.
    3) prohibit non-operating personnel into the radiation safety zone, pay attention to professional ethics, to ensure personal safety. Use the equipment according to the instructions required for maintenance, maintenance, repair; cross operations to implement, four understand three will not forget; equipment failure, the first power failure, after the check, promptly excluded, without disease operation.
 
    Formal security did not prepare the manufacturer in the security machine factory, the console will be accompanied by a clear operational guidelines, according to the instructions on the operation is no problem.